Measurement-computing Analyzer488 Manual de usuario Pagina 117

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 281
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 116
Section 4 Serial Controller
4.23
CLEAR
The
CLEAR
command causes the Analyzer488 to issue a Device Clear (DCL)
bus command. If optional addresses are included, the Selected Device Clear (SDC)
command is issued to all specified devices. IEEE 488 bus devices which receive a
DCL or SDC command normally reset to their power-on state.
This command does not have a query option.
TYPE High Level Controller command
SYNTAX CLEAR [addr[,addr]]
addr
is an IEEE 488 bus device address (primary address with
optional secondary address).
,
is the address separator, either a comma, a slash [/] or a period
[.].
RESPONSE None
MODE High Level Controller
BUS STATES ATN•DCL (all devices)
ATN•UNL,MTA,LAG,SDC (selected devices)
QUERY None
RESPONSE
EXAMPLES
PRINT #1,"CLEAR"
Issue a Device Clear to all
devices.
PRINT #1,"CLEAR 12,18"
Issue a Selected Device Clear to
devices 12 and 18.
Vista de pagina 116
1 2 ... 112 113 114 115 116 117 118 119 120 121 122 ... 280 281

Comentarios a estos manuales

Sin comentarios