30
CB-7011/CB-7011D, CD-7018 User’s Manual
2.9 $AA4
Description: Read Synchronized Data
Note: The command is for CB-7011/11D/11P/11PD only.
Syntax: $AA4[CHK](cr)
$ delimiter character
AA address of reading module (00 to FF)
4 command for reading synchronized data
Response: Valid Command: >AAS(Data)[CHK](cr)
Invalid Command: ?AA[CHK](cr)
Syntax error or communication error may get no re-
sponse.
! delimiter for valid command
? delimiter for invalid command or the module does not
receive command #** before the command $AA4.
AA address of response module(00 to FF)
S status of synchronized data, 1 = first time read, 0 =
has been read
(Data) synchronized data, format reference Sec. 1.10
Example:
See example of Sec. 2.2 #**
Related Command:
Sec. 2.2 #**
Comentarios a estos manuales