Measurement-computing CB-7080 Manual de usuario Pagina 38

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 74
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 37
CB-7080 & CB-7080D Counter/Timer User's Guide $AA4
2-20
$AA4
Description: Read the status of digital filter. Refer to "Digital filter setting" for more information.
Syntax: $AA4[chk](cr)
$ A delimiter character
AA 2-character HEX module address, from 00 to FF
[chk] 2-character checksum. If checksum is disabled, no [chk]
(cr) 0x0D
Response:
Valid response !AAS[chk](cr)
Invalid response ?AA[chk](cr)
no response Syntax error, communication error or address error
! A delimiter character indicating a valid response
? A delimiter character indicating an invalid response
AA 2-character HEX module address
S=0 digital filter is disabled
S= 1 digital filter is enable
[chk] 2-character checksum. If checksum is disabled, no [chk]
(cr) 0x0D
Examples:
Digital filter is disabled:
command: $014(cr)
response: !010(cr)
Digital filter is enabled:
command: $024(cr)
response: !021(cr)
Vista de pagina 37
1 2 ... 33 34 35 36 37 38 39 40 41 42 43 ... 73 74

Comentarios a estos manuales

Sin comentarios