Measurement-computing CB-7080 Manual de usuario Pagina 29

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 74
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 28
CB-7080 & CB-7080D Counter/Timer User's Guide $AA0L
2-11
$AA0L
Description: Read the minimum input signal width at low level. Refer to "Digital filter setting" for more
information.
Syntax: $AA0L[chk](cr)
$ A delimiter character
AA 2-character HEX module address, from 00 to FF
[chk] 2-character checksum. If checksum is disabled, no [chk].
(cr) 0x0D
Response:
Valid response !AA(data)[chk](cr)
invalid response ?AA[chk](cr)
no response Syntax error, communication error or address error
! A delimiter character indicating a valid response
? A delimiter character indicating an invalid response
AA 2-character HEX module address
(data) 5-character decimal value for min. width at low level. The unit is microseconds and
the range can be from 2 µs to 65535 µs.
[chk] 2-character checksum. If checksum is disabled, no [chk].
(cr) 0x0D
Examples:
Min. width=20 s
command: $010H(cr)
response: !0100020(cr)
Min. width=2000 s = 2 ms
command: $020H(cr)
response: !0202000(cr)
Vista de pagina 28
1 2 ... 24 25 26 27 28 29 30 31 32 33 34 ... 73 74

Comentarios a estos manuales

Sin comentarios