DAQFlex Software User's Guide DAQFlex Message Reference Programming messages AI
35
Get the A/D data rate in samples per channel for a specified channel.
Message
"?AI{ch}:DATARATE"
Response
"AI{ch}:DATARATE=value"
ch
The channel number.
value
The data rate in S/s.
OFFSET
Get the calibration offset coefficient for the specified channel.
Message
"?AI{ch}:OFFSET"
Response
"AI{ch}:OFFSET=value"
ch
The channel number.
value
The calibration offset.
Example
"?AI{0}:OFFSET"
RANGE
Set the range value for a specified channel.
Message
"AI{ch}:RANGE=value"
Response
"AI{ch}:RANGE"
ch
The channel number.
value
The range value.
Example
"AI{0}RANGE= value"
Note
Call an AI:RANGES Reflection message to get the supported ranges. If the message
returned does not include PROG%, then the message does not apply to the device.
If ch is not specified, all channels are set to the range value.
If RANGE is not specified, the device power up default value is used.
Get the range value for a specified channel.
Message
"?AI{ch}:RANGE"
Response
"AI{ch}:RANGE=value"
ch
The channel number.
value
The range value.
Example
"?AI{0}:RANGE"
Note
Call an AI:RANGES Reflection message to get the supported ranges. If the message
returned does not include PROG%, then the message does not apply to the device.