DAQFlex Software User's Guide Hardware Reference USB-1208FS-Plus
103
Component
Supported
Property/Command
Set/Get
Supported Values
RANGE
Set/Get
BIP20V, BIP10V, BIP5V, BIP4V, BIP2PT5V,
BIP2V, BIP1PT25V, BIP1V (differential
mode)
BIP10V (single-ended mode)
RANGE{ch}
SAMPLES
Set/Get
0 to N
(0 = continuous scan; N = 32-bit)
SCALE
Set/Get
ENABLE, DISABLE
START
STATUS
Get
IDLE, RUNNING, OVERRUN
STOP
TRIG
Set/Get
ENABLE, DISABLE
XFRMODE
Set/Get
BLOCKIO, SINGLEIO
AITRIG
REARM
Set/Get
ENABLE/DISABLE
TYPE
Set/Get
EDGE/RISING, EDGE/FALLING
LEVEL/HIGH, LEVEL/LOW
AO
Get
2 (number of analog output channels)
RES
Get
U12
SCALE
Set/Get
ENABLE, DISABLE
AO{ch}
RANGE
Get
UNI5V
VALUE
Set
0 to 4095
0 to 4.99878 when SCALE is enabled
AOSCAN
BUFSIZE
Set/Get
COUNT
Get
HIGHCHAN
Set/Get
0 to 1
INDEX
Get
LOWCHAN
Set/Get
0 to 1
RATE
Set/Get
0.01 S/s to 50 kS/s
SAMPLES
Set/Get
0 to N
(0 = continuous scan; N = 32-bit)
SCALE
Set/Get
ENABLE, DISABLE
START
Set
STATUS
Get
IDLE, RUNNING, UNDERRUN
STOP
Set
CTR
Get
1 (number of counter channels)
CTR{ch}
START
Set
STOP
Set
VALUE
Get
0 to 4,294,967,295
Set
0 (resets the counter to 0)