Section 3 Command Descriptions
3.25
The
M8
command will cause a
Service Request
to be generated in addition
to
DIO4
being set if the self test fails. The
DIO4
bit is cleared after the
controller sends a
Status
command
(U0X)
and reads the status string from
the
Digital488.
DIO5
The
DIO5
bit is set after an entire command string has been received and
processed by the
Digital488.
The bit is clear while the
Digital488
is
processing commands which have been received from the controller. When
used with the
M16
command, a
Service Request
will also be generated
when the
DIO5
bit is set. An
Execute
command
(X)
must be received
before the
DIO5
bit can be cleared.
DIO6 DIO6
is not used, and is always a logic zero.
DIO7
When the
Digital488
generates a
Service Request,
the
DIO7
will be set to a
logic one. This is used by the controller to determine that the
Service
Request
was generated by the
Digital488.
DIO8 DIO8
is not used, and is always a logic zero.
Example:
CLEAR 718
reset the
Digital488
OUTPUT 718;"M4X"
select SRQ on Bus error
OUTPUT 718;"F7X"
send an invalid bus command.
ERROR and SRQ LEDs should illuminate
SPOLL (718)
display should be
84
(64+16+4)
64 denotes the
Digital488
was the source of the SRQ. 16 denotes the
Digital488
is
READY for more commands. 4 denotes a Bus error.
When serial polled,the SRQ LED will turn off.