Section 3 Command Descriptions
3.15
Example 1: Select automatic hardw are handshaking using dual primary addressing
mode.
PRINT#1,"CLEAR08"
reset the Serial488/4
PRINT#1,"OUTPUT08;P1X"
select port 1 as the current port
PRINT#1,"OUTPUT08;G0N0X"
select automatic hardware handshaking
Example 2: Select software handshaking w ith baud clock output using secondary
addressing mode.
PRINT#1,"CLEAR0800"
reset the Serial488/4
PRINT#1,"OUTPUT0800;P2X"
select port 2 as the current port
PRINT#1,"OUTPUT0800;g1n3X"
select software handshaking w ith baud
clock output