15A. Driver488/DRV Commands III. COMMAND REFERENCES - 15. Command References
III-286 Personal488 Users Manual, Rev. 3.0
CHECK LISTENER
SYNTAX
CHECK LISTENER pri-addr[sec-addr]
pri-addr
is a primary device address in the range
0
to
30
.
Sec-addr
is an optional two-digit secondary device address in the range
00
to
31
.
RESPONSE
1 if listener found
0 if listener not found
MODE
CA
BUS STATES
ATN
MTA, UNL, LAG, (check for NDAC asserted)
SEE ALSO
FIND LISTENER, BUS ADDRESS
EXAMPLE
PRINT#1CHECKLISTENER 1501
INPUT#2,N
IF N=1 THEN PRINT LISTENER FOUND
IF N=0 THEN PRINT LISTENER NOT FOUND
The
CHECK LISTENER
command checks for the existence of a device on the IEEE 488 bus at the
specified address.
CLEAR
SYNTAX
CLEAR [addr[,addr]]
addr
is a device address (primary with optional secondary) or an external
device name.
RESPONSE
None
MODE
CA
BUS STATES
ATN
DCL (all devices)
ATN
UNL, MTA, LAG, SDC (selected devices)
SEE ALSO
RESET
EXAMPLES
PRINT#1,CLEAR
Issue a Device Clear to all devices.
PRINT#1,CLEAR12,18
Issue a Selected Device Clear to devices 12 and 18.
PRINT#1,CLEAR DMM
Issue a Selected Device Clear to the device DMM.
The
CLEAR
command causes the Device Clear (
DCL
) bus command to be issued by Driver488. If the
optional addresses are included, the Selected Device Clear (
SDC
) command is issued to all specified
devices. IEEE 488 bus devices that receive a Device Clear or Selected Device Clear command
normally reset to their power-on state.
CLOCK FREQUENCY
SYNTAX
[CLOCK]FREQUENCY frequency
frequency
is the actual clock rate in megahertz rounded up to the nearest whole
number of megahertz.
RESPONSE
None
MODE
Any
BUS STATES
None
SEE ALSO
RESET
EXAMPLE
PRINT#1, CLOCK FREQUENCY 8
The
CLOCK FREQUENCY
command specifies the IEEE 488 adapter internal clock frequency. The clock
frequency depends upon the design and jumper settings of the interface board. The specified clock
frequency must be the actual clock rate in megahertz rounded up to the nearest whole number of
megahertz. For example, the MP488 and MP488CT boards use a fixed clock frequency of 8 MHz.