9F. QuickBASIC II. SOFTWARE GUIDES - 9. Driver488/SUB
II-162 Personal488 Users Manual, Rev. 3.0
rv% = ioDisarm% (ieee%, 0) ;
Note that an external device handle is acceptable in this and other functions which actually refer to the
interface; the external device handle will simply be translated to the handle of the interface to which the
device is attached, prior to taking action. This translation is fully automatic within Driver488/SUB and
requires little overhead, so you need not and should not go to great lengths to pass an interface handle,
if your application structure makes the use of external device handles the more logical choice.
Reading Driver Status
Your application may interrogate Driver488/SUB at any time to determine its status and other
information.
Status
information is returned in a structure provided by the application and can be
displayed by the
showstat
function shown below:
rv%=ioStatus%(ieee%,substat)
CALL showstat (substat)
Another function to display the information contained in the
Status
structure could be:
SUB showstat (substat AS IeeeStatus)
PRINT SC :; substat.SC,
PRINT CA :; substat.CA,
PRINT Primaddr :; substat.Primaddr
PRINT Secaddr :; substat.Secaddr,
PRINT SRQ :; substat.SRQ,
PRINT addrChange :; substat.addrChange
PRINT talker :; substat.talker,
PRINT listener :; substat.listene,
PRINT triggered :; substat.triggered
PRINT cleared :; substat.cleared,
PRINT transfer :; substat.transfer,
PRINT byteIn :; substat.byteIn
PRINT byteOut :; substat.byteOut
END SUB
External Device Initialization
Refer to the device manufacturers documentation on specific requirements for initializing your
IEEE 488 instrument. In the case of the ADC488, appropriate initialization involves sending it a
Clear
command and placing it into
Remote
mode:
rv% = ioRemote% (adc%)
rv% = ioClear% (adc%)
For our hypothetical application, we also wish to have the ADC488 generate a service request should it
detect a command error. This involves sending a command string consisting of textual data to the
ADC488:
rv% = ioOutput & (adc%, M8X)
We may also wish to perform other initialization and configuration. In this case, we set up the
ADC488 (
adc
) in the following configuration:
Differential inputs (A0)
Scan group channel 1 (C1)
Compensated ASCII floating-point output format (G0)
Channel 1 range to +/-10V (R3)
One-shot trigger on talk (T6)
The command to perform this configuration combines the above strings and adds the
Output
command for the ADC488:
rv% = ioOutput& (adc%, A0C1G0R3T6X)