Buffer Position
1 2 3 ... 39 40 41 42 ... 59 59 60
Scan
941 942 943 ... 979 980 981 982 ... 998 999 1000
If the total number of acquired scans is less than the buffer size, then the scans will not overwrite earlier scans
and the buffer is already in a natural chronological order. In this case, daqAdcBufferRotate does not
modify the buffer.
In WaveBook/512 applications, daqAdcBufferRotate will only work on unpacked
samples.
Prototypes
C/C++
daqAdcBufferRotate(DaqHandleT handle, PWORD buf, DWORD scanCount, DWORD
chanCount, DWORD retCount);
Visual BASIC
VBdaqAdcBufferRotate&(ByVal handle&, buf%, ByVal scanCount&, ByVal
chanCount&, ByVal retCount&)
Program References
None
4.2-4 Daq API Command Reference 988594 Programmer’s Manual