3 HARDWARE INSTALLATION
3.1 BASE ADDRESS
Unless there is already a board in your system using address 300h (768 Decimal), leave the switches as they are set at the factory.
In Figure 3-1, the CIO-DAS6402 is set at base address 300h. See Figures 3-6 and 3-7 for the locations of the switches
Figure 3-1. Base Address Switches
3.2 D/A OUTPUT RANGE SWITCH (CIO-DAS6402/16 ONLY)
The analog output ranges of the CIO-DAS6402/12 are set via software. The analog output ranges of the CIO-DAS6402/16 are set
by dip switches on the board (Figure 3-7). Figure 3-2 shows the the allowable switch settings and Table 3-1 gives the range/switch
settings.
Figure 3-4. D/A Output Range Switches
2
SW
A9
A8
A7
A6
A5
A4
HEX
200
100
80
40
20
10
98
7
6
5
4
BASE ADDRESS SWITCH
- Address 300H shown here.
CIO-DAS6402/16 Analog Output
Configuration Switch
(shown as +/- 10 Volt full-scale)
O
N
1 2 3 4 5