CB-7013, CB-7033 Users Manual
2.12 $AAF
Description: Read Firmware Version
Syntax: $AAF[CHK](cr)
$ Delimiter character
AA Address of reading module (00 to FF)
F Command for read firmware version
Response: Valid Command: !AA(Data)[CHK](cr)
Invalid Command: ?AA[CHK](cr)
Syntax error or communication error may get no
response.
! Delimiter for valid command.
? Delimiter for invalid command.
AA Address of response module (00 to FF)
(Data) Firmware version of module.
Example:
Command: $01F Receive: !01A2.0
Read address 01 firmware version, returns version A2.0.
Command: $02F Receive: !01B1.1
Read address 02 firmware version, returns version B1.1.