9-2 Maintenance, Service, and Part Replacement
05-26-00
WavePort User’s Manual
Fan Filter: Cleaning and Replacement
To Clean the Filter Media:
1. Turn WavePort “OFF” and unplug the unit.
2.
Remove the four screws from the Metal Guard.
3.
Remove the Metal Guard and the Guard-Media-Retainer (the later is a snap-together assembly).
4.
Using mild detergent, clean the Media while it is still encased between the Guard and the Retainer.
5. Rinse under running water; then air-dry.
6. Secure Guard-Media-Retainer and Metal Guard to WavePort using the four Screws that were removed in
step 2.
Fan Filter Media with Retainer and Guards
To Replace the Filter Media:
1.
Perform steps 1 through 3 from above.
2. Pry the Guard (plastic) from the Retainer.
3. Remove the old Media.
4.
Clean the Guard and Retainer, if needed.
5.
Position new filter Media between Guard and Retainer.
6. Snap the Guard, Media, and Retainer together.
7.
Secure Guard-Media-Retainer and Metal Guard to WavePort using the four Screws.