PCIM-DAS1602/16 User's Guide Installing the PCIM-DAS1602/16
37
19
20
1
The red stripe
identifies pin # 1
2
40
1
39
Key
Figure 2-12. BP40-37 cable
Field wiring, signal termination and signal conditioning
2-9
You can use the following MCC screw terminal boards to terminate field signals and route them into the PCIM-
DAS1602/16 board using the C37FF-x or C37FFS-x cable:
! CIO-MINI37 – 37-pin screw terminal board.
! SCB-37 – 37 conductor, shielded signal connection/screw terminal box that provides two independent 50-
pin c
onnections.
MCC provides the following analog signal conditioning products for use with the PCIM-DAS1602/16 board:
! ISO-RACK16 – Isolated 16-channel, 5B module rack for analog signal conditioning and expansion.
! ISO-DA02 – Isolated 2-channel, 5B module rack for analog signal conditioning and expansion.
MCC provides the following digital signal conditioning products for use with the PCIM-DAS1602/16 board:
! CIO-ERB08 – 8-channel, Form C relay accessory board for digital signal conditioning.
! CIO-ERB24 – 24-channel, Form C relay accessory board for digital signal conditioning.
! SSR-RACK08 – 8-channel, solid-state relay mounting rack for digital signal conditioning.
! SSR-RACK24 – 24-channel, solid-state relay mounting rack for digital signal conditioning.