D-4 Device Connector Reference
977296
Appendix D
P4 – P4 is a 100-pin connector that shares signal connections with the P1, P2, and P3 connectors. P4
offers no additional I/O. You can connect a DBK200 Series Option to P4 via a CA-195 cable to
essentially distance the P1, P2, P3 connection from the DaqBook/2000X. See the following Caution.
CAUTION
Signal conflicts between a DaqBook/2000 Series device’s P1, P2, P3 connectors and its
P4 connector can result in erroneous readings and possible equipment damage.
Therefore, when connections have been made to P1, P2, and/or P3, use caution when
making connections through P4, and visa versa.
Use a CA-209D CE Cable Kit in electrically noisy environments. The kit includes a
3-foot long shielded cable, two grounding pigtails, two cable clamps, and 4 screws. The
CE Compliance chapter of the DaqBook/2000 Series User’s Manual (p/n 1103-0901)
provides additional information.
Reference Note: The document section, System Connections and Pinouts, contains pinouts for P1,
P2, P3 and P4. A copy of the document is included in the DaqBook/2000 Series User’s
Manual (p/n 1103-0901). The manual can be viewed from the data acquisition CD via the
<View PDFs> button on the CD’s opening screen.