15
IRQDATA is set according to the condition of the S1 and S0 bits of BASE + 5 register. This bit is set to 1
when:
S1 S0
0 0 Single A/D conversion is done.
0 1 Not applicable.
1 X Total counter = 0 (meaning the total counter has reached terminal count), OR, the FIFO
reaches half full (512)
TRGSTAT: Pre-trigger status. Reads 1 if trigger has occurred. Pre-trigger must have been enabled.
OVRUN: Over-run status bit. Is set to 1 at the A/D conversion that occurs after:
A DT-Connect handshake fails, or
The FIFO buffer is full.
This bit is cleared (set to 0) by either DTEN = 0 or by clearing the FIFO (write 0 to
BASE + 6). Stop the pacer before clearing the overrun bit.
TOOFAST: When set, the FIFO buffer is cleared automatically when half-full.
If this bit is set to 1, the DT-Connect must be in use or many conversions may be lost. The interrupt on
FIFO half-full will still function when this bit is set so that interrupt must be handled correctly. Set this bit
and use DT-Connect whenever the A/D conversion rate desired exceeds the REP-INSW rate of the target
computer.
PRETRIG: When set to 1, enables pre-trigger mode. TRIG0 must be set to 1 also.
When set to 0, disables pre-trigger mode.
DTEN: When set to 1, enables DT-Connect data transfers. Disables at 0.
CTR0: Selects source of CTR0 clock input. If set to 1, source is on-board
XTAL: Gated by pin 21 of the 37-pin connector.
If set to 0, the source is the clock signal you supply to pin 21.
TRIG0: When set to 1, enables pin 25 as the external trigger (trigger signal must be active high).
When set to 0, the external trigger is disabled. The trigger is a low to high transition which initiates a
block of A/D samples. The external trigger can be used only with the on-board XTAL pacer signal. If the
A/D is externally paced, it is not possible to use an external trigger.
4.6.3 Four-Bit Digital I/O Registers
BASE ADDRESS + 3
When read:
765432 10
0 0 0 0 DIN 3 DIN 2,also
CTR0 Gate
DIN 1 DIN 0,also
TRIGIN
Vista de pagina 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 37 38

Comentarios a estos manuales

Sin comentarios

Securitron AQU128B manuali

Manuali dei proprietari e guide per l'utente per Alimentatori elettrici Securitron AQU128B.
We fornisce 1 manuali pdf Securitron AQU128B per scaricare gratuitamente in base al tipo di documento: Manuale Utente






Più prodotti e manuali per Alimentatori elettrici Securitron

Modelli Tipo di Documento
AQU244 Manuale Utente   Securitron AQU244 User Manual [de] [fr] [it] , 5 pagine
AQU243 Manuale Utente   Securitron AQU243 User Manual, 6 pagine
AQU243-8C Manuale Utente   Securitron AQU243-8C User Manual, 7 pagine
AQU126B Manuale Utente   Securitron AQU126B User Manual, 7 pagine
AQU126-4F Manuale Utente   Securitron AQU126-4F User Manual, 6 pagine
AQD6 Manuale Utente   Securitron AQD6 User Manual, 4 pagine
AQD5B Manuale Utente   Securitron AQD5B User Manual [en] [es] [it] , 7 pagine
AQD3B Manuale Utente   Securitron AQD3B User Manual, 7 pagine
AQD5 Manuale Utente   Securitron AQD5 User Manual [it] , 4 pagine
AQM20 Manuale Utente   Securitron AQM20 User Manual, 8 pagine
AQD3 Manuale Utente   Securitron AQD3 User Manual, 15 pagine