Table 3-2. Board Registers
Counter ControlNot usedBASE + 7
Load Counter 2Read Counter 2BASE + 6
Load Counter 1Read Counter 1BASE + 5
Load Counter 0Read Counter 0BASE + 4
Not usedNot usedBASE + 3
OP1-OP4, INTE & MUX
Address
EOC, IP1-IP3, IRQ, MUX
Address
BASE + 2
Start 12 bit A/D conversionA/D Bits 1(MSB)-8BASE + 1
Start 8 bit A/D conversionA/D Bits 9-12(LSB)BASE
WRITE FUNCTIONREAD FUNCTIONADDRESS
3.2 A/D DATA REGISTER
BASE ADDRESS
0000A/D12
LSB
A/D11A/D10A/D9
01234567
A read/write register.
READ
On read, it contains the least significant four digits of the analog input data.
These four bits of analog input data must be combined with the eight bits of analog
input data in BASE + 1, forming a complete 12-bit number. The data is in the
format 0 = minus full scale. 4095 = +FS.
WRITE
Writing any data to the register causes an immediate 8-bit A/D conversion.
BASE ADDRESS + 1
A/D8A/D7A/D6A/D5A/D4A/D3A/D2A/D1
MSB
01234567